When the first hard cold arrives, many homeowners notice water or frost on the inside of their windows, or drips from a sun tunnel diffuser in a hallway or bathroom. Condensation on the room side of the glass doesn’t by itself mean you need new windows. Before you replace anything, check three things: indoor humidity, air leaks around the window frame, and where warm, moist air is going in the attic.
Why condensation shows up in winter
University of Minnesota Extension lists condensation on windows during the winter as a symptom of excess moisture in the home. It says moisture problems may occur when relative humidity is above 50%, that cold winter conditions call for low humidity to prevent condensation, and that 25% in winter to 50% in summer is generally considered healthy and comfortable for people and better for the house.
The colder it gets outside, the lower indoor humidity needs to be. The Center for Energy and Environment (CEE), based in Minneapolis, publishes this general winter guide:
| Outdoor temperature | Indoor relative humidity |
|---|---|
| 20 to 40°F | below 40% |
| 10 to 20°F | below 35% |
| 0 to 10°F | below 30% |
| -10 to 0°F | below 25% |
| -20 to -10°F | below 20% |
| -20°F or colder | below 15% |
CEE says that if you see consistent moisture build-up on windows or walls, there is too much moisture in the air, and you should turn off the humidifier and lower its set point before turning it back on. Extension’s other steps include reducing moisture sources such as bathing, cooking and humidifiers, checking that bathroom and kitchen exhaust fans work, and in winter, opening windows slightly for a short time to let moist air out.
Check the installation: the gap behind the trim
Humidity isn’t the only factor. In this short video, we show an installation issue we check for: loose-fill or poor insulation in the gap between the window frame and the wall framing, hidden behind the interior casing. Our first recommendation is to fill that gap properly. The video’s description specifies low-expansion, window-specific spray foam, because other foams can put too much stress on the frame.
Guidance from the U.S. Department of Energy’s Building America Solution Center lines up with that:
- If spray foam is used, it should be a low-expansion foam designated for windows and doors.
- Fibrous insulation alone shouldn’t be relied on to block airflow.
- Ordinary expanding foam can swell enough to distort the jambs and cause problems opening and closing the window, and it will often void window warranties.
- The seal should be applied toward the interior edge of the window, so the gap toward the exterior can still drain.
In practice that means cutting the caulk line so the paint doesn’t peel, removing the casing, sealing the gap with the right foam, and reinstalling the trim. If you’d rather have it checked first, call us.
Sun tunnel condensation
Sun tunnels bring daylight into halls, baths and closets, but in a Minnesota winter they can drip. VELUX’s support guidance explains that a sun tunnel doesn’t produce water: the moisture comes from outside the tunnel and gets in through small gaps along it, then shows up as droplets or pools on the diffuser. Its fix is to check the full length of the tunnel for gaps, re-tape them, and check the insulation wrap.
VELUX’s installation instructions for its rigid sun tunnel call for:
- a tight joint between the ceiling ring and the ceiling
- taping all joints
- a tight joint between the ceiling ring and the vapor barrier, if one is installed
- good insulation on the attic side around the tunnel, either by spraying the perimeter with polyurethane foam or by making sure the insulation is snug around the tunnel
The Building America Solution Center adds sealing all gaps at the ceiling plane with caulk or spray foam, sealing tube seams with metal tape or mastic, and covering the tube with R-8 or greater duct insulation that includes a vapor barrier. For cleaning, the video shows a simple trick: a small suction cup with a grip removes the diffuser without scraping your knuckles on the ceiling. Use a stable step stool.
Check where the bath and kitchen fans vent
Fans that exhaust into the attic add moisture to the same space the sun tunnel runs through, which is why our sun tunnel video says to keep them out of the attic. The Building America Solution Center recommends looking in the attic to make sure bathroom and kitchen exhaust fans vent outside, because moisture from fans exhausting into the attic can cause mold growth and damage to the wood. The Department of Energy’s consumer guide to attics calls fans vented into the attic a major source of moisture. Extension also recommends sealing openings that let warm, moist air into walls, ceilings and the attic.
Attic and window checks are free unless service is needed.
Permits in Eden Prairie
If the fix turns into new windows or new fan ducting, check permits first. The City of Eden Prairie says building permits are required for work on the permanent weather-resistive surfaces of a home, including siding, windows and roof, and that structural alterations or repairs to those items also require a permit. It also requires mechanical permits to install, alter, repair or extend any ventilation or exhaust system. The city posts a Window Replacement Info handout and says all work is subject to inspection, with a permit record card listing the inspections for each project. Who pulls the permit is confirmed in the written scope for your project. Eden Prairie also reminds homeowners that Minnesota requires residential builders, remodelers and roofers to be licensed; you can check any contractor with the Minnesota Department of Labor and Industry license lookup.
When the window itself is the problem
If moisture is between the panes of glass, or the sash or frame is damaged, the room-side fixes above won’t reach it, and it is time to look at the window itself. See our window replacement page for what that involves.
Working with Foremost Exteriors
Foremost Exteriors is based at 4740 W 124th Street in Savage and serves Eden Prairie and the rest of the south and west Twin Cities metro; see our Eden Prairie page. Minnesota Residential Building Contractor License #BC777460. More about us on our company facts page. Call or text (952) 495-5545 or contact us.
Frequently asked questions
Does window condensation mean I need new windows?
Not by itself. University of Minnesota Extension treats winter window condensation as a sign of excess indoor moisture. Check humidity and the insulation and air seal around the frame first. Moisture between the panes is a different problem.
What indoor humidity should I keep in winter?
Lower as it gets colder. The Center for Energy and Environment’s guide runs from below 40% at 20 to 40°F outside down to below 15% at -20°F or colder.
What kind of foam should be used around windows?
Low-expansion foam designated for windows and doors. The Building America Solution Center warns that ordinary expanding foam can distort the jambs and often voids window warranties.
Why is my sun tunnel dripping in winter?
Moist air is getting into the tunnel through gaps and condensing on cold surfaces. VELUX’s instructions call for a tight ceiling ring joint, taped joints and good insulation around the tunnel on the attic side.
Can bathroom fans vent into the attic?
They shouldn’t. The Building America Solution Center recommends confirming bath and kitchen fans vent outside, because moisture exhausted into the attic can cause mold and wood damage.
Do I need a permit to replace windows in Eden Prairie?
Yes. Eden Prairie requires building permits for work on windows, siding and roofs, and mechanical permits for work on ventilation or exhaust systems.
Can you check my windows in Eden Prairie?
Yes. Eden Prairie is in our service area. Attic and window checks are free unless service is needed.
Sources
- University of Minnesota Extension: Controlling moisture problems in your home
- Center for Energy and Environment: Managing indoor humidity levels all year round
- U.S. DOE Building America Solution Center: Air sealing window and door rough openings
- U.S. DOE Building America Solution Center: Air sealing light tubes
- U.S. DOE Building America Solution Center: Look at exhaust fans for venting to outside
- U.S. Department of Energy: Consumer guide to durable attics (PDF)
- VELUX: Installation instructions for rigid sun tunnel TZR (PDF)
- VELUX support: How to fix condensation on my sun tunnel
- City of Eden Prairie: Building Inspections and Permits page (edenprairiemn.gov)
- Minnesota Department of Labor and Industry: License and registration lookup